145mm Depth Evd Series Cooling Tower Drift Eliminator
145mm depth EVD Series Cooling Tower Drift Eliminator FEATURES - Anti-aging, high water absorption.- Low airflow resista
Basic Info
Model NO. | EVD Series |
Ventilation Mode | Natural Ventilation |
Air Contact Form | Wet and Dry |
Air Contact Way | Open |
Tower Shape | Square |
Noise Level | Low |
Application Fields | Industrial |
Certification | ISO |
Condition | New |
Transport Package | Woodencase 20gp/40gp Container |
Specification | Height: 145 mm |
Trademark | NEWIN |
Origin | China |
HS Code | 8419909000 |
Production Capacity | 500000/Year |
Product Description
145mm depth EVD Series Cooling Tower Drift EliminatorFEATURES
- Anti-aging, high water absorption.- Low airflow resistance, high strength.- Easy installation and long service life.- Can be the replacement of air inlet louver.PROPERTIES
With different request in EVD drift eliminators, like length and width, materials or thickness, etc, please inform us your detailed request to get correct solution and offer. Newin could cover all customer requirements. Fill media in flame retardant or anti-bacterial execution are also available on request.Module Length (Max) | mm | 2440 |
Module Width (Max) | mm | 500 |
Module Depth | mm | 145 |
Flute Height | mm | 25 |
Flute Corrugation Angle | degrees | - |
Sheet Thickness - Before Forming | mm | 0.45 |
Sheet Thickness - After Forming | mm | 0.4 |
Max. application temp. (short time) - PVC | °C | 60 |
Max.operating temp. (short time) - High temp. | °C | 80 |
Customized size and thickness available for special request. Contact Newin for details. |
STRUCTURE & INSTALLATION DRAWING
Newin supply structure & installtion drawing advice with jobsite storage advice and quality control report along with shipment to make attention to customers when they receive the materals. OEM or special mold design also available on request.APPLICATION & USAGE
Newin EVD celluar drift eliminator is applicable for Evapco cooling tower series of ESWA, ESWB, AT UT USS, LSTE&LPT, SUN, with SGS test in ASTM Standards to keep high quality infill to get the high efficiency of the cooling tower. Inform us the tower model or size, we will estimate the Nos of sheets needed for your cooling tower replacing.APPLICABLE COMMERCIAL STANDARDS
Sheets material is strictly followed below SGS test with ASTM standards. Each property or all properties as below tested by your products are also vailable on request.Property | Test Method | Values | ||
Specific Gravity | ASTM D792-13Method B | 1.426g/cm3 | ||
Oxygen Index | ASTM D2863-13 | 34.50% | ||
Tear Strength | ASTM D1004-13 | X direction | 111 N | |
Y direction | 121 N | |||
Tensible Test | ASTM D 882-12 | Tensile Strength | X direction | 51.1 MPa |
Y direction | 45.3 Mpa | |||
Elongation atBreak | X direction | 87% | ||
Y direction | 56% | |||
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin | ||||
Statements and methods presented are based upon the best available information and practices known to Newin. Conditions of use may vary and are beyond control, the user should undertake sufficient tests to determine the suitability for any intended use of the material. |
FILED DATA FOR CELLUAR DRIFT ELIMINATOR REPLACEMENT
Fill in below measurements data for your maintenance cooling tower or reparing projects demand quality and reliability, count on Newin, site visit or maintenance service, engineered to fit the cooling tower fills or components.
Send to us