1830mm Length PVC Drift Eliminator for Cooling Tower
1830mm Length PVC Drift Eliminator for Cooling Tower NEWIN cooling tower drift eliminators Drift eliminators are designe
Basic Info
Model NO. | MBD |
Cooling Method | Counter Flow or Cross Flow |
Ventilation Mode | Mixing Ventilation |
Material | PVC |
Air Contact Form | Wet and Dry |
Air Contact Way | Open |
Tower Shape | Blade or Cellular |
Noise Level | Low |
Application Fields | Industrial |
Certification | ISO, CTI |
Condition | New |
Warranty | One Year |
Usage | Cooling Tower |
Application | Replace for Cooling Tower |
Height | 146mm |
Transport Package | Wood Packing |
Specification | CTI |
Trademark | NEWIN |
Origin | China |
HS Code | 84195000 |
Production Capacity | 15000 Sets /Year |
Product Description
1830mm Length PVC Drift Eliminator for Cooling Tower
NEWIN cooling tower drift eliminators
Drift eliminators are designed to capture large water droplets caught in the cooling tower air stream.The eliminators prevent the water droplets and mist from escaping the cooling tower.Eliminators do this by causing the droplets to change direction and losr velocity at impact on the blade walls and fall back into the tower.MBD-146 Eliminator
Feaures
- Made of flame retardant pvc material
- Anti-aging, low airflow resistance, high strength
- Optimal droplet capture
- easy installation and long service life
Specification
Model--MBD | PVC |
Max.length | depend on customer demand |
Width | depend on customer demand |
Height | 146 mm |
Continuous operation tempperature | 50ºC |
Max.applicationtemp. (short term) | 60ºC |
Color | Black |
Application | Marley cooling tower, counter flow cooling tower |
Packing and Loading: LCL shipment: by plywood pallet/case/carton, FCL shipment: by container
Trade Terms: EXW, FOB, CFR,CIF, DDU.
Payment term: T/T, L/C, West Union
Minimum Order Quantity: 1000pcs
MBD drift eliminator Pictures --- cooling tower drift eliminator
Packing & Shipment
PVC Plastic sheet(after molding) Physical and mechanical property
No. | Item | symbol | unit | index | test method | |
1 | density | ρ | g/cm3 | ≤1.55 | GB/T 1033 1-2008 | |
2 | tensile strength | lengthways | σt | MPa | ≥42.0 | GB/T 13022-91 |
crosswise | ≥38.0 | |||||
3 | tear strength | lengthways | σtr | kN/m | ≥150 | GB/T 1130-91 |
crosswise | ≥160 | |||||
4 | Folded in half Coldness Resistance Temperature | ordinary type | tb | ºC | ≤-8 | DL/T 742-2001 |
Frigostabile type | ≤-18 | |||||
5 | oxygen index | OI | -- | ≥30 | GB/T 2406 1-2008 |
Cooling tower plastic parts code and standard
GB/T 1033-1986 plastic density and relative density experiment method
GB/T 1040-1992 plastic tensile performance test methods
GB/T 1633-1979 thermoplastic softening point (d) test method
GB/T 1843-1996 plastic cantilever beam impact test method
GB/T 2406-1993 plastic combustion performance test method, oxidation index
GB/T 13022-1991 plastic film tensile performance test methods
GB/T 1190-1991 plastic rectangular tear performance test methods
Replacement for other brand cooling towers:
Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.You may be also interested in below PVC Air Inlet Louver/Cooling Tower Air Intake Louver/Cooling Tower Louver/Cooling Tower Air Inlet Louver,
please visit to below website below for more details.
http://newinmachine.en.made-in-china.com
http://newinmachine.en.made-in-china.com
http://newinmachine.en.made-in-china.com
Contact person
Erin Lian
Cell: +86-18172211369
Tel : +86-755-23077266
*******************************************
Website : http://newinmachine.en.made-in-china.com
http://newinmachine.en.made-in-china.com
Send to us